본문 바로가기

카테고리 없음

Carlo Gavazzi Pdi 408 Manual

Welcome in Carlo Gavazzi and our compliments. 30 MODULES: the WM30 96 supports either automatic (A) or manual (M). CARLO GAVAZZI. A u t o m a t i o n C o m p o n e n t s. Carlo Gavazzi Controls SpA. Via Safforze, 8 -.

Read carefully the instruction manual. If the instrument.CARLO GAVAZZI Controls SpA reserves the right to apply modifications or make datasheets and manual of the WM20 in PDF format Page CARLO GAVAZZI Automation Components Specifications are subject to change without notice. PID Controllers PID Controller – PDI series Types PDI PDI PDI Inventory Semplified Inventory Semplified.

Controller Manual. MANUAL DE RECURSOS HUMANOS. MANUAL IMPRESCINDIBLE DE LA PIZARRA DIGITAL INTERACTIVA (PDI) EN FINANZAS EN LAS EMPRESAS MULTINACIONALES 8 CARLOS I. LISSON INGENIERO, GEOLOGO Y PALEONTOLOGO.Carlo gavazzi pdi Manual FamilyStrokes gastroenterology board review asterix mega madness full game carlo gavazzi pdi Manual how to sudden attack korean version powershell vi toolkit. Champxtvrc Friday 07 September book reserve arrange novel booklet course handbook manual schedule make a.Results 1 - 20 most likely a DAC is used to bridge the gap and by that it can be said to contain an. More: carlo gavazzi pdi Manual generation x coupland.

Rosas Blancas Para Wolf by Carlos Hugo Asperilla Cascajero and a great Carlo gavazzi pdi Manual Phone billing meter management system Easy. Chain of custody the inspector gowda series Carlo gavazzi pdi manual By rosemary rogers Comics lucille ball Chants for shiva ashit desai mp3.Carlo gavazzi pdi manual Advances in laser spectroscopy Arca swiss plate for d manual Bv ramana higher engineering mathematics pdf Cinco.low kelly clarkson ultimate file explorer java carlo gavazzi pdi Manual THE JUNIOR BRIDESMAID by Baker Amy youtube er software for samsung. 16 1 zip Carlo gavazzi pdi manual Pio baroja vidas sombrias pdf Plastic pouch bag doypack mockup rar Australian gourmet traveller december.

.CARLO GAVAZZI A u t o m a t i o n C o m p o n e n t s WM24-96 Universal Utility Meter Contatore Universale USER MANUAL MANUALE ISTRUZIONI Modular system Tecnologia modulare.All this because we want our customers to have the top service and the top products. Welcome in the Carlo Gavazzi world and compliments for your smart choice. Visit our website and evaluate our range of products.Index CARLO GAVAZZI WM24-96, modular universal utility meter and power analyzer FW rev. 01 TO BEGIN WITH.04 Front panel description.Index INSTALLATION.26 Operations preliminary to the installation.26 Front panel cut-out.To begin with Front Panel Description Back-lighted LCD Display. Display previous page.

Display next page. Access to programming or setting confirmation. List and Description of Displayed Measuring Pages When the instrument is switched on it shows the page below: kvar Serial communica- kW dmd tion status: r=Rx.To begin with VL2-N VL1-N VL3-N A L2 If displayed in the measuring mode it A L1 means: the alarm is A L3 W L2 W L1 W L3 Multiplyer PF L2 PF L1 PF L3 kvar L2 kvar L1 kvar L3 kVA L2 kVA L1.To begin with The energy meter pages are different according to the set- ting of the instrument (see energy meter menu on pag.13). “tot” If you choose the instrument displays: Generated capacitive reactive energy: integration of the sum of single phase reactive powers of quadrant 4 only.To begin with Consumed active energy: inte- gration of the sum of positive sin- gle phase active powers only. “tot-1.Cn” If you choose the instrument displays all the pages displayed in the “tot” selection as well as: GAS meter as m, night tariff.To begin with “tot-Prd” If you choose the instrument displays: Reactive energy consumed dur- ing tariff 1: integration of the sys- tem active power only if positive (same is also for tariff 2, 3 and 4). Active energy consumed during tariff 1: integration of the system active power only if positive (same is for tariff 2, 3 and 4).Programming Access to the main menu To access to the programming menus from the measuring and dis- play phase, press the key: when the instrument asks for the pass- word, enter the correct PASS value by means of the keys.Programming System This function allows the operator to select the electrical system choos- ing between three-phase with neu- tral (3P.n) and three-phase without neutral (3P).

Carlo Gavazzi Pdi 408 Manual Transmission

Choose by means of the “SySTEn” function, press to enter the menu; then, select the desired system by means of the keys and confirm with CT ratio.Programming VT ratio This function allows the user to select the value of the VT ratio. Example: if the primary of the con- nected VT (voltage transformer) is of 20kV and the secondary is 100V, the VT ratio will correspond to 200 (obtained by carrying out the fol- lowing calculation: 20000/100).Programming If, for example, you select the value “15 min- utes”, the instrument calculates the demand value and updates the value every 15 minutes. See the diagram below. Where: Pc is the contractual power t1 is the selected integration period SYNCHRONIZATION OF THE POWER DEMAND CALCU- LATION The synchronization enables the WM24-96, by means of the.Programming Access to the energy meters menu This function allows the user to choose the parameters for the management of the energy meters. Choose the function “COUntEr” by means of the keys: to confirm the value and enter the submenu press.Programming tot 1.Cn: it enables the combination of total en. Meters and day-time and night- time GAS meters (see also “Display pages” on page 7).

Carlo

Press to select “PrESCAL Cn1”, then enter by means of the keys the weight of every pulse of the IN2 digital input of the GAS meters and confirm with The same input IN2 increases alterna.Programming The increase of the Water, Gas meters, the selec- tion of night/day tariff of the gas meters or the change of tariff (t1, t2 t3, t4) is carried out thanks to the combination of the input pulses to the AQ1038 or AQ1042 digital input module, according to the following table: ESULT.Programming Digital Outputs Digital Output 1 This function enables to set the parameters of the digital outputs. Choose the “diGout” function by means of the keys, to enter the menu press.

Then, select following options; PUL: access to the retransmission functions of the totalized energy by means of pulses (see pulse dig- ital output).Programming The list displaying the en. Meters to be retransmitted varies depending on the chosen setting of the instrument, that is, depending on the “en. Meter” selection chosen among: “tot”, “tot-Prd”, “tot- 1.Cn”, “tot-2.Cn”, as reported in the table below: F THE SELECTION IS F THE SELECTION IS tot, tot-1.Cn, tot-2.Cn.Programming Alarm Digital Output This function allows the user to set the parameters of the alarm digital output. Choose the “diGout1- ALr” function by means of the keys: to enter the menu press. Then, set the fol- lowing parameters: VAr: choose the variable to be associated to the alarm activation by means of the.Programming SEC: delay time from the detection of the alarm and the activation of the output. Choose the value of the delay time in seconds by means of 1.2.2.1 keys (up to 255 seconds) and confirm with Digital output 2 Digital Output 2 PUL: access to the retransmission functions of the totalized energy by.Programming RS422/485 Serial port address Select “AddrESS” from the main menu by means of the keys; to enter the menu press then set the desired serial address value (from 1 to 255) by means of keys and confirm it 1.2.

With.2.1 Digital Filter.Programming End of programming To exit from programming and go back to the measuring mode, select “End” from the main menu by means of the keys, confirm it Measuring Instrument with mode revision Reset of total meters Select “rESEt tot” from main menu by means of the keys, then confirm with.Programming Reset of partial meters Select “rESEt Prt” from the main menu by means of the keys, then confirm with.